Smart pigging for fire heaters, Re-boilers & Furnaces
Suitable For
Visbreakers.
Coker units.
Vacuum Heaters.
Steam Generators.
Hydro-crackings Units.
Atmospheric Heaters.
Inspection Of
Studded Tubes.
Finned Tubes.
Bare Tubes.
Size Range
3 to 12 Inches.
Advantages
Bidirectional Verifiable Ultrasonic profiling and Internally/Externally inspection.
High inspection speed and Fast Reporting.
Measuring wall Thickness, inner and outer pipe wall.
Determining types and positions of defects in the coil.
Full profiling ( Ultrasonic signal reflections ) for the coil.
Provides critical weld data.
2D, 3D visuals.
Data is recorded during inspection and safely stored.
Data takes place in many phases (tables, graphs, reports).
Indicating assessment and lifetime remaining for the coil.
Identifications
Internal corrosion.
External corrosion.
Flame impingement.
Flow Erosion.
Diameter changes.
Creep.
Bulging.
Swelling.
Ovalities.
Dents.
Fretting.
Bends.